Continuous passive motion lower limbs

Presentation
Presentation

Knee, hip and ankle CPM (Continuous Passive Motion) devices, used during the first phase of rehabilitation to aid in recovery after joint surgery. The purpose of this therapy is the restoration of range of motion in patients with pathologies both surgically treated such as synovectomy, arthroscopic surgery for calcific tendonitis, acromioplasty, tenotomy, and non surgically treated such as brachial plexus lesions, humerus fractures, tendinopathies, arthritis.

 

Our FISIOTEK devices let the specific joint move through a an extended period of time, gradually moving the affected joint through a prescribed arc of motion. The goals of this rehabilitation are control post-operative pain, reduce inflammation, and protect the healing repair or tissue.

 

The FISIOTEK 3000 equipment line is operated by a direct-current motor controlled by a micro-card. Functions programmable via a fixed keyboard. A movable keyboard allows patients to start and stop movement by pressing the relevant keys. The limb positioning area is on top the device and is adjustable to the size of the patient's limb. The adjustment depends on the limb length, as measured from the greater trochanter to the malleolus.

 

TREATED PATHOLOGIES:

  • Arthrotomy, arthroscopy
  • Treatment following mobilization
  • Surgical treatment of fractures
  • Reconstructive surgery
  • Endoprosthetic implants
  • Operations on soft tissue

 

More info
More info

FISIOTEK 3000 MODEL COMPARISON

 

TECHNICAL FEATURES

CODICE ARTICOLO

XRI001

XRI002

XRI003

XRI004

XRI005

 

3000 GS

3000 G

3000 E

3000 TS

3000 N

 Knee and hip mobilization

X

X

X

X

X

 Ankle mobilization

     

X

 

 Use of memory card

X

   

X

 

 Speed control (flexion/extension)

X

X

 

X

 

 Speed control

   

X

 

X

 Workout duration control

X

X

X

X

X

 Resistance

X

X

X

X

X

 Automatic extension increase

X

X

 

X

 

 Automatic flexion increase

X

X

 

X

 

 Pause during extension

X

X

 

X

 

 Pause during flexion

X

X

X

X

X

 Warm Up cycles

X

X

X

X

X

 Adjustable foot rest

X

X

X

   

 Knee movement range

-10° ÷ 120°

-10° ÷ 120°

-10° ÷ 120°

÷ 110°

÷ 110°

 Ankle movement range

     

20° ÷ 0° ÷ 40°

 

 Hip movement range

-7° ÷ 115°

-7° ÷ 115°

-7° ÷ 115°

-7° ÷ 115°

-7° ÷ 115°

 Automatic extension increase limit

X

X

 

X

 

 Automatic flexion increase limit

X

X

 

X

 

 Repetitions at extension limit

X

X

X

X

 

 Repetitions at flexion limit

X

X

X

X

 

 